upload
Varian Medical Systems, Inc.
Industry:
Number of terms: 14663
Number of blossaries: 0
Company Profile:
Varian Medical Systems, Inc., headquartered globally in Palo Alto, California, is the world's leading manufacturer of medical devices and software for treating cancer and other medical conditions with radiotherapy, radiosurgery, proton therapy, and brachytherapy. The company supplies informatics ...
Green man image used in the Patient Verification application to indicate one of eight orientations.
Industry:Medical devices
Üç hangi üretir ham 2D projeksiyonlar 2D projeksiyonları düzeltilmiş bir CBCT dataset yeniden adımları. Normalleştirme ve Logaritmik dönüşüm yanı sıra, ön iki farklı adımları, spektrum düzeltme ve dağılım düzeltme içerir: • spektrum düzeltme için ışın-sertleşme etkisi Dedektör spektrum ışık hassasiyeti yanı sıra x-ışını tüpü ve hangi aracılığıyla her ışın geçer (titanyum filtre, papyon filtre vb.) malzeme çıkış spektrum için muhasebe tarafından dengeler. Ayrıca nesne tarafından neden olduğu kiriş sertleşme (tahmin) düzeltmesi yapar. • Dağılım düzeltme nesnesine Yansımalar, makine yapılandırma ve precomputed simülasyonlar içinde görünür dayalı her projeksiyon X-ray dağılım miktarını tahmin ediyor. Bu dağılım katkı yansımalar ölçülen X-ray iletimde dan çıkarılır tahmini. Ayrıca CBCT imar bakın.
Industry:Medical devices
Konum bilgileri bağımsız ikincil pozisyon sensörü. Bu bilgiler, birincil pozisyon sensörü göstergesi doğrulamak için kullanılır.
Industry:Medical devices
A rotating assembly in the treatment head that places beam shaping elements, such as flattening filters and scattering foils, into the beam path.
Industry:Medical devices
En yaygın bir DVH görüntüsünü (alternatif: diferansiyel DVH)
Industry:Medical devices
Enerji geçiş konumlandırır servo-DRIVE bir mekanizma.
Industry:Medical devices
A measure of the total energy absorbed by a patient or object during exposure to radiation.
Industry:Medical devices
The date in which the last simulation image was acquired.
Industry:Medical devices
Yeşil adam görüntü hasta doğrulama uygulama sekiz yönelimleri birini belirtmek için kullanılır.
Industry:Medical devices
One of three steps in the reconstruction of a CBCT dataset, which produces corrected 2D projections from raw 2D projections. In addition to normalization and logarithmic conversion, preprocessing consists of two distinct steps, spectrum correction and scatter correction: • Spectrum correction compensates for the beam-hardening effect by accounting for the output spectrum of the X-ray tube and the material through which each ray passes (Titanium filter, bowtie filter, and so on) as well as the spectrum sensitivity of the detector. It also performs a (guessed) correction of the beam hardening caused by the object itself. • Scatter correction estimates the amount of X-ray scatter in each projection based on the object visible in the projections, the machine configuration, and precomputed simulations. This estimated scatter contribution is subtracted from the measured X-ray transmission in the projections. See also CBCT reconstruction.
Industry:Medical devices